ORION ME – Orion® Migratable Endpoint

The ORION® Migratable endpoint (ME) is a two-way water endpoint for mobile applications with the capability of migrating to fixed network mode to support future utility capabilities.

In addition to providing the current and snapped daily reading, the endpoint two-way functionality allows users to capture data profile information wirelessly, without having to directly access the endpoint, during the normal reading process. An ORION Migratable endpoint is easily upgraded to an ORION Fixed Network endpoint (SE) through a software license.

The ORION Migratable endpoint is a member of the time-tested ORION family of products from Badger Meter, designed for maximum flexibility. Since 2002, the ORION product family has been providing comprehensive Advanced Metering Analytics (AMA) for interval meter reading and data capture using both oneway and two-way communications.

Category:

Description

FUNCTIONALITY

Operation: The endpoint continuously monitors the encoder circuit. At predetermined intervals, the endpoint broadcasts the totalized reading value along with other meter data to the mobile collection devices.

Activation: The endpoints offer a Smart Activation feature. All ORION endpoints are shipped in an inactive, non-transmitting state. After the endpoint is installed, it begins broadcasting data when the encoder senses the first usage of water. No field programming or tools are required to activate the endpoint.

Broadcast Mode: Once activated, the endpoints begin transmitting in mobile priority mode. After installation, using the endpoint two-way communication, an endpoint transmits its meter data every six seconds.

Data Profiling: The endpoints store up to 90 days of hourly historical interval meter data within nonvolatile memory. Output Message: The endpoint broadcasts its unique serial number, current meter reading, daily snapped meter reading and applicable status indicators for mobile reading collection.

APPLICATION

Configurations: Available in integral, remote or endpoint-only configurations, the endpoint can be deployed in indoor, outdoor and pit applications. The endpoint electronics and battery assembly are fully encapsulated in epoxy for environmental integrity.

Meter Compatibility: When attached to a Badger Meter encoder, the endpoint is compatible with all current Badger Meter Recordall® Disc, Turbo Series, Compound Series, Combo Series and Fire Service meters and assemblies, and with E-Series® Ultrasonic and M-Series® Electromagnetic flow meters.

Encoder Compatibility: The endpoint is suitable for use with all Badger Meter encoders as well as the following Badger Meter approved three-wire encoder registers that have a manufacture date of 2000 or newer, are programmed into the AMR/AMI three-wire output mode and have three-wires connected:

  • Elster C700 Digital, InVISION and ScanCoder® encoders and evoQ4 meter (encoder output); Hersey® Translator; Master Meter® Octave®
  • Ultrasonic meter encoder output; Metron-Farnier Hawkeye; Mueller
  • Systems 420 Solid State Register (SSR) LCD; Neptune® ProRead, E-Coder® and ARB-V®; and Sensus® Electronic Register encoder (ECR) and ICE.

Compatibility: The endpoint is suitable for use with all Badger Meter encoders as well as the following Badger Meter approved three-wire encoder registers that have a manufacture date of 2000 or newer, are programmed into the AMR/AMI three-wire output mode and have three-wires connected: Elster C700 Digital, InVISION and ScanCoder® encoders and evoQ4 meter (encoder output); Hersey® Translator; Master Meter® Octave® Ultrasonic meter encoder output; Metron-Farnier Hawkeye; Mueller Systems 420 Solid State Register (SSR) LCD; Neptune® ProRead, E-Coder® and ARB-V®; and Sensus® Electronic Register encoder (ECR) and ICE.

Additional information

Dimensions

5.125 in. (H); 1.75 in. (W) at top;
2.125 in. (W) at bottom

Broadcast Frequency MHz Band

FCC regulated 902…928 MHz
frequency hopping modulation

Operating Temperature Range Storage and Meter Reading

-40…60° C (-40…140° F)
based on storage and meter reading.
RF output may be reduced by
extremely low temperatures. The
water meter should not be subjected
to temperatures below freezing.

Humidity

0…100% condensing

Battery

One (1) lithium thionyl chloride
C cell (nonreplaceable)

Battery Life

20 years (calculated)